Product Description
Price is for each.
Manufacturer Part Number: TB6575C1000
HONTB6575C1000 120/240/277vac 3 Speed Digital Fan Coil Suitepro Thermostat; 2 Or 4 Pipe Manual/Auto Changeover, Heat/Cool/Auto, 50-90F
Part Description:
HONTB6575C1000 120/240/277vac 3 Speed Digital Fan Coil Suitepro Thermostat; 2 Or 4 Pipe Manual/Auto Changeover, Heat/Cool/Auto, 50-90F
Part Description:
- Fan Coil Thermostat
- Type Digital, 3-Speed, Auto/Manual Changeover
- Cover Type Rectangular Horizontal/Vertical
- Color Premier White
- Voltage Rating 120/240/277 Volt AC at 50/60 Hertz
- Current Rating 2.4 Amp (Fan)/1 Amp (Heat/Cool Relay) at 277 Volt AC
- Size 5-13/16 Inch Width x 1-1/8 Inch Depth x 3-13/16 Inch Height
- Approval UL 873, CSA, FCC
- Display Type LCD
- Humidity 5 to 95 Percent Relative (Non-Condensing)
- Switch Position Off-Heat-Cool-Auto (System), High-Medium-Low-Auto-Off (Fan)
- Ambient Temperature 50 to 90 Deg F
- Includes Direct Mounting on Horizontal 2 Inch x 4 Inch Junction Box, Mount on Vertical 2 Inch x 4 Inch or 4 Inch x 4 Inch Junction Box
Features / Benefits
- Simple, Intuitive User Interface and Ease of Installation
- Attractive Modern Styling Ideal for Hotels and Condos
- Digital Display of Ambient Temperature, Set Point, Mode Icons When Cooling or Heating Relays Operate, When Energy Savings Mode is Active and Fan Status
- Four Buttons Allow Manual Control of System Operation, Fan Speed and Temperature Set Point Adjustment
- Versaspeed Fan Ramp Algorithm Automatically Adjusts Low, Medium, High Fan Speed
- Activity Sensing Algorithm Sets Back Thermostat to Economy Mode
- Auto Fan Rest Option Sets Back Fan to Auto Mode
- Energy Savings Mode - External Energy Savings Input from Dry Contact Such as Time Switch, Occupancy Sensor or Hotel Cardkey Overrides Comfort Set Point with Selectable Setback Heating or Cooling Set Points
- Energy Savings Input Configurable as a Normally Open or Normally Closed Dry Contact
- Proportional Plus Integral (P+I) Control Algorithm for Precision Temperature Regulation
- Selectable C or F
- Adjustable Deadband, in Auto Changeover Mode, for Heat and Cool Control
- Adjustable Maximum Heating and Minimum Cooling Set Point Limits
- Installer Setup Mode Allows Changes of Operating Parameters
- EEPROM Permanently Retains User Settings, Including Set Points, During Power Loss (No Batteries Required)
- Capability to Display Temperature Sensor Failure for Easier Troubleshooting